General questions about Clean

The biggest difference is how large an area they can treat.

  • Clean 30 is suitable for smaller spaces.
  • Clean 60 covers medium-sized areas.
  • Clean 120 is designed for larger rooms and more extensive treatments.

This way, you can choose the model that best matches your needs and room size.

An ozone generator that produces ozone, which is a form of oxygen with three oxygen atoms. These neutralize and eliminate bad odors and mold. The technology breaks down and neutralizes odor molecules, making it particularly effective against odors such as mold smell, smoke, and pet odor.

Ozone can be harmful to both pets and plants. Just like humans, pets and plants should not be in the room when the ozone generator is running. Always leave the room empty and ensure thorough ventilation before re-entering the space.

Clean goes deep to eliminate odor molecules, mold, bacteria, viruses and allergens – for a cleaner, healthier, and completely odor-free environment.

Ozoneair Clean is extremely effective against musty odors. Its advanced IonFusion technology helps neutralize odor molecules and completely remove musty smells.

Yes, Ozoneair Clean can be used to remove mold odor from a variety of surfaces, including fabric, wood, concrete, and more.

Depending on the severity of the odor, you may start seeing results immediately after the first use.

Yes, it gets everywhere. Clean fills the entire space with ozone. It seeps everywhere, into cracks and crevices. Even under floors, in walls and ceilings. All odors you can detect are in contact with the air, and the ozone takes the same path as the air to eliminate them at their source.

Clean removes all existing odours in the space at that given time. If the odour is reintroduced, the treatment must be repeated. For example, if you have a problem with odours in a summer cottage or RV, it is usually sufficient to treat it once each spring. This is because odours reappear when the spaces are unheated and poorly ventilated.

The Technology

Ionfusion® is an advanced technology that combines the power of ozone and ionization to neutralize and break down pollutants at a molecular level. It is used to effectively eliminate odors and mold in various environments.

IonFusion® generates ozone and negatively charged ions, which together neutralize odor molecules and mold spores. These reactive molecules convert harmful substances into harmless ones such as oxygen and water.

No, although Ionfusion® is safer than traditional ozone generators, it is recommended not to be in the treatment room when the unit is active. Ozone in high concentrations can be irritating to the respiratory tract and skin, so it is important to follow the safety instructions.

IonFusion® offers a more controlled and effective process by combining ozone with ionization. This technology enables faster and more comprehensive neutralization of contaminants, thereby reducing the risk of harmful by-products that can arise with ozone treatment alone.

Usage and Maintenance

  1. Connect the power cable to the product and a wall socket.
  2. Turn the knob to set the room size (in automatic mode).
  3. Press START/STOP to start the treatment.

Ozoneair Clean has three different modes: Automatic, Manual, and Continuous. Each mode is designed for different types of needs and experience levels. Below is a detailed overview to help you choose the right mode for your situation.

1. Automatic Mode – recommended for most users

Automatic mode is the smartest and most user-friendly option. It is suitable for both private individuals and businesses who want to sanitize without having to make advanced settings.

How it works:

  • You set the room size by turning the knob (e.g., 20 m², 50 m² etc.).
  • The machine automatically calculates an optimal treatment time based on the area and a standard ceiling height of approximately 2.5 meters.
  • Once the treatment is complete, you should wait an additional 6 hours before entering and ventilating.

2. Manual Mode – when you want more control

Manual mode is suitable for those who want to adjust the ozone strength and treatment time themselves.

How it works:

  • Press MODE once to activate manual mode.
  • Turn the knob to select the desired effect (percentage level).
  • Press TIME to select treatment time: 1, 2, 4, 6, 8, or 12 hours.

When to use manual mode?

  • For particularly stubborn odors (e.g., smoke, mold, or pets).
  • If you want to adjust the strength in smaller spaces.
  • If the room has an unusual ceiling height – lower ceilings may require less time, higher ceilings more.

3. Continuous Mode – for professional use only

The continuous mode is the most powerful and should only be used by professionals or experienced users.

How it works:

  • Activated by pressing MODE twice.
  • Ozone is produced without the machine itself limiting the time – you decide when to stop the treatment.

When is this mode used?

  • Sanitation of vehicles
  • Quick spot treatments of small spaces
  • Particularly difficult odor problems where you need full control and experience

For Clean 60 and Clean 120, the oxygen plates need to be replaced after approximately 4,000 hours of operation. On the Clean 30, the oxygen plates are integrated and therefore cannot be replaced.

The machine has an estimated lifespan of approximately 4,000 operating hours. For the Clean 60 and Clean 120, you can then replace the oxygen plates to further extend its lifespan.

A treatment takes approximately 4 hours, depending on the size of the room. On the dial, you set the number of square meters to be treated, and the treatment time is automatically adjusted to the size of the space.

Remove all living organisms from the room. Set the dial to the correct number of square meters, press start, and leave the room. The machine will perform the treatment and switch itself off when finished.

Use an ozone generator as often as needed. It effectively eliminates all odors present in the room at the time of treatment, meaning you rarely need to repeat the treatment unless the same odor source reappears.

  • Acute needs (e.g., fire damage): One treatment is usually sufficient to eliminate contaminants and odors.
  • Indoor smoking: To keep the air free from smoke odor, you may need to repeat the treatment regularly, depending on how often smoking occurs.
  • Musty odors in cabins, basements, caravans, etc.: To keep these spaces fresh, a treatment every spring is recommended. It usually takes time for the odor to build up again to a noticeable level.

No, it is not safe to be in a room while an ozone generator is in operation. Ozone can be harmful to inhale. Always leave the room and ensure it is well ventilated after use before re-entering.

Ozone degrades relatively quickly. After the ozone generator is turned off, it usually takes between 30 minutes and 2 hours for the ozone to return to safe levels. After treatment, ventilate the room to speed up the degradation of residual ozone.

Troubleshooting guide

Possible cause:

  1. The power cable is not connected correctly
  2. The fuse has blown

Solution

  1. Check that the power cable is correctly connected.
  2. Replace the fuse

Possible cause:

  1. The product has not been started.

Solution

  1. Press the knob to start.

Possible cause:

  1. The oxygen plates are dirty.

Solution

  1. Clean the oxygen plates (60 and 120 models only).

This section allows you to give an in-depth explanation, including step-by-step guidance, specific product details, or policy clarifications, ensuring customers get a complete answer to their question without confusion.

Possible cause:

  1. Oxygen plates are used up.
  2. Delay is active.

Solution

  1. Replace the oxygen plates (60 and 120 models only).
  2. Wait two minutes.

Order, delivery and warranty

The Clean series comes with a 5-year warranty.

Years 1–3: Full warranty
Years 4–5: Warranty valid, but labor costs apply

In addition, a 14-day trial period when you order your product.

The Clean series comes with a 14-day risk-free trial, so you can experience the difference for yourself.

Please note that the product must be in its original condition and complete with all accessories for the right of return to apply.

To use your 14-day right of return, please fill out our return form here.

Return shipping label:

Within 72 hours, you will receive a return shipping label via email along with instructions on how to return the product.

You can easily find and order acid plates here.

If you wish to order by phone, you can also do so at 0771-366 366.

Contact us

Call us on +46771-366 366 or email us at kundservice@ozoneair.com